Many older bench grinders, buffers, drill presses and saws run from a simple toggle or rocker switch. If power drops out while the switch is on, the machine starts again by itself when power returns, possibly while someone is changing a wheel or clearing a part. An anti-restart control puts a magnetic contactor between the supply and the motor. After start is pressed, the contactor stays closed through its own holding contact; when power is lost, it drops out and stays open until someone presses start again. This is often called no-voltage release or power loss drop-out. For woodworking machinery, OSHA 1910.213 requires provision to prevent automatic restarting where a restart after a power failure could injure the operator.
Related: emergency stop controls, machine interlock systems, bench grinder guards and drill press guards.
Anti-restart keeps a machine off after a power loss until someone presses start. An E-stop is a manual control that stops the machine when someone presses it. The Odiz anti-restart enclosure provides both, with start, stop and E-stop buttons working through the same contactor.
For woodworking machinery, OSHA 1910.213 requires provision to prevent automatic restarting after a power failure where a restart could injure the operator, and OSHA 1910.217 calls for a similar motor starter on mechanical power presses. For other machines, OSHA's general machine guarding rule, 1910.212, applies, and a risk assessment shows whether an unexpected restart is a hazard.
When stop is pressed, the brake disconnects the AC supply and feeds direct current into the motor windings. The resulting magnetic field slows the rotor, so a grinding wheel, buffer or saw blade stops sooner than it would by coasting. DC injection braking is used on AC induction motors, so check the motor type before ordering.
Plug-in units such as the MAKESafe Power Tool Brake install quickly between the outlet and the machine. Hardwired enclosures mount on the machine and are wired into its supply, which makes them harder to bypass. Choose based on the machine's voltage and motor, how it is installed and whether it is moved between outlets.