Free shippingOn every online order shipped within the contiguous U.S. Valid only for orders placed through our website.
Safety Through Innovation · Made in the USA
Free shippingOn every online order shipped within the contiguous U.S. Valid only for orders placed through our website.
Machine interlock systems, including time-delayed sandblaster interlocks and interlocked drill press and mill guards.
Showing all 3 products
An interlock connects a guard or door to the machine’s control circuit. While the guard is open the machine cannot start, and opening it during a cycle sends a stop signal. Closing the guard should not restart the machine; on Odiz anti-restart interlocked guards, the operator presses start deliberately. Where a hazard continues after the stop signal, such as a coasting spindle or airborne dust, guard locking or a time delay keeps the door closed until the hazard has passed.
OSHA 1910.212(a)(3)(iv)(e) lists milling machines among the machines that usually require point of operation guarding. ANSI B11.8 covers manual milling, drilling and boring machines, and B11.23 covers machining centers and CNC milling, drilling and boring machines. ISO 14119 sets principles for designing and selecting interlocking devices associated with guards, including ways to minimize their defeat, and ISO 13849-1 covers the design of the control system that processes the interlock signal. See also drill press guards, milling machine guards and anti-restart and motor brake systems.
A standard interlock detects that a guard has opened and stops the machine. Guard locking also holds the guard shut until it is safe to open, either until motion has stopped or until a set time has passed. Use guard locking when the hazard would still be present by the time someone could reach it.
Opening a blast cabinet door during operation, or before the cabinet has cleared, can release silica dust toward the operator. A time-delayed interlock keeps the door locked for a set period, and safety air valves can hold the pneumatics until conditions are safe. Odiz engineers each system to the cabinet and process.
It should not. On Odiz anti-restart interlocked guards, closing the guard only allows the machine to run again, and the operator still has to press start. This keeps a spindle from starting while a hand is still near the chuck or the work.
Odiz flip-up and side-swinging drill press guards are available with an optional interlock system that adds start/stop/E-stop controls, no restart on power loss and an LED guard indicator. For other guards, Odiz can recommend an interlock switch and control package that suits the guard and machine.