Free shippingOn every online order shipped within the contiguous U.S. Valid only for orders placed through our website.
Safety Through Innovation · Made in the USA
Free shippingOn every online order shipped within the contiguous U.S. Valid only for orders placed through our website.
Emergency stop controls, including E-stop enclosures with optional shrouds, pull cord kits and stop/E-stop foot pedal bars.
Showing all 4 products
An emergency stop gives anyone at the machine a fast, obvious way to halt hazardous motion when something goes wrong, such as a jammed part, a caught sleeve or a person in the wrong place. Actuating the device opens the stop circuit, and E-stop buttons and pull-cord switches typically latch until they are deliberately reset. Resetting should only permit a restart; the machine should not run again until someone presses start. Because an E-stop depends on a person noticing the hazard and reacting, it supplements guards and safeguarding devices and does not replace them.
The E-stop with yellow plastic enclosure puts an E-stop button with 3-pole contacts at any operator position. The optional shroud rings the button to reduce accidental presses from carts, tools or elbows while keeping it easy to reach.
A rope-pull switch lets an operator stop the machine from anywhere along a cable. The three-roller bending machine E-stop pull cord kit retrofits older roll benders that have no safeties, putting a stop within reach along the rolls and helping keep people back from the machine.
The stop/E-stop foot pedal bar runs along lathes, mills and other machines so the operator can stop the machine with a foot when both hands are busy. Optional adjustable lengths of 12–20 in., 32–52 in. and 52–90 in. fit different machines.
ISO 13850 sets functional requirements and design principles for the emergency stop function on machinery, whatever energy the machine uses, and NFPA 79 covers the electrical equipment of industrial machines, including their control circuits. ANSI B11.0 covers general machine safety and risk assessment, B11.12 covers roll forming and roll bending machines, and B11.15 covers bar, pipe, tube and shape bending machines. OSHA 1910.212(a)(3) requires point of operation guarding, and for woodworking machines 1910.213 requires a power control that lets the operator cut off power without leaving the point of operation. See also anti-restart enclosures and roller guarding.
Within easy reach of every place an operator works, including control stations, loading points and the back of the machine if people work there. On long machines such as roll benders, a pull cord along the hazard zone gives a stop from any position, and a foot pedal bar helps when both hands are occupied.
It should not. Resetting the E-stop should only permit a restart, and the operator then presses start deliberately. Pairing E-stops with an anti-restart contactor keeps the machine off after a reset or a power loss until the start button is pressed.
A shroud is a raised ring around the button that reduces accidental presses from carts, tools or elbows. It should still leave the button easy to strike in an emergency. Choose the optional shroud where accidental stops are a problem, such as beside a busy aisle or at a crowded workstation.
No. An E-stop depends on someone noticing the hazard and reacting, so it cannot keep hands out of the point of operation. OSHA 1910.212 requires guarding of points of operation and other machine hazards, and E-stops, pull cords and foot bars are added to that guarding as a backup.