Compressed gas cylinder inspection app for cylinders in storage and in use. The Odiz App checklist draws on OSHA 29 CFR 1910.253 and 1910.101: gas identification, securing, valve caps, leaks, damage, hydrostatic test dates and separation of oxygen from fuel gas. Record the gas type, cylinder size, pressure rating and material, then inspect monthly.
Request information
OSHA rules for compressed gases and oxygen-fuel gas systems, together with DOT requalification rules, cover how cylinders are marked, stored and inspected. The Odiz App checklist references these rules and defaults to a monthly inspection.
Compressed Gases General Requirements
Oxygen-Fuel Gas Welding and Cutting
Cylinder Requalification
Default Inspection Frequency
Problems that show up with compressed gas cylinders, and the checklist items that catch them.
Unsecured Cylinders
Cylinders standing loose without a chain, strap or rack to keep them upright.
Missing Valve Caps
Valve protection caps left off cylinders that are not in use or connected for use.
Unlabeled Cylinders
Cylinders with no gas name marked, or markings that can no longer be read.
Oxygen Next to Fuel Gas
Oxygen stored closer than 20 feet to fuel gas cylinders without a noncombustible barrier between them.
Expired Test Dates
Cylinders past their hydrostatic test or requalification interval still in service.
Leaks and Damage
Hissing, frost or odors at the valve or regulator, and dents, bulges or corrosion on the cylinder.
A compressed gas cylinder stores a large amount of energy. A cylinder that falls and breaks off its valve can be propelled with great force, and a leaking fuel gas or oxygen cylinder can feed a fire.
OSHA 29 CFR 1910.101(a) requires employers to determine that compressed gas cylinders under their control are in a safe condition, to the extent visual inspection can tell. A monthly check with a dated record shows that each cylinder was labeled, secured, capped and separated, and whether its hydrostatic test date was current.
Key criteria cited in the Compressed Gas Cylinders checklist.
Gas Identification
Cylinders are legibly marked with the chemical or trade name of the gas, by stenciling, stamping or labeling that is not readily removable.
Valve Protection Caps
Where a cylinder is designed to accept a cap, the valve protection cap is in place, hand-tight, except when the cylinder is in use or connected for use.
Oxygen Separation
Oxygen cylinders in storage are separated from fuel gas cylinders or combustible materials by at least 20 feet, or by a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least one-half hour.
Cylinder Requalification
DOT sets requalification intervals for specification cylinders, and the interval depends on the cylinder type. The checklist confirms the hydrostatic test date is within its interval.
A consistent way to inspect every cylinder on site and follow up on what fails.
Lookup by Tag or ID
Scan the QR tag or enter the Equipment ID to open a cylinder's record and checklist.
Gas Details on Record
Gas type, cylinder size, pressure rating and material are stored with each cylinder.
Photos of Defects
Failed items require a photo, a description and a recommendation.
Tracked Fixes
Each failure becomes a corrective action with an assignee, a due date and a verification step.
Overdue Alerts
Upcoming and overdue inspections show on the To-Do list and in the Daily Overdue Inspection Digest.
Shared Assignments
Assign inspections to one or more people, and any assignee can complete them.
Keep a dated history of every cylinder inspection, with the inspector's name and a PDF report on each record.
Common questions about compressed gas cylinder inspections in the Odiz App.
29 CFR 1910.253(b)(4)(iii) calls for at least 20 feet, or a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least one-half hour. The Odiz App checks this as its own item.
Yes. One item confirms the hydrostatic test date is current and the cylinder is within its requalification interval, referencing DOT 49 CFR 180.209. Intervals depend on the cylinder specification, so check the markings on each cylinder.
Gas type, cylinder size (small under 40 cu. ft., medium 40 to 150 cu. ft., or large over 150 cu. ft.), pressure rating in psi and cylinder material.
Compressed gas cylinders default to a monthly inspection, and the next due date follows that frequency after each submission. Overdue cylinders appear in the To-Do list and the Daily Overdue Inspection Digest.
A failed item requires a photo, a description and a recommendation. The finding moves into Corrective Actions, where it gets an owner, a due date and a verification step before it closes.
Yes. The Odiz App includes a training module on compressed gas cylinders, and completions count toward each worker's training record.
Compressed gas cylinders are heavy, high-pressure containers. A cylinder that tips over, loses its cap or leaks at the valve can injure people and damage property. The Compressed Gas Cylinders inspection in the Odiz App covers 15 checks on labeling, securing, valve caps, leaks, cylinder condition, test dates, storage separation and connected equipment, and records who inspected each cylinder and when.
Add each cylinder in the app and attach a QR tag. The add-equipment wizard asks for the manufacturer and model, and if that model is already in the shared catalog its details fill in automatically. At inspection time, open Equipment Lookup, scan the tag or enter the Equipment ID, and answer each item Pass, Fail or N/A. Inspections can be assigned to one or more people, and any assignee can complete them.
Each result is dated, recorded with the inspector's name and saved to the cylinder's inspection history with a PDF report. The next due date follows the monthly default frequency, and overdue cylinders appear in the To-Do list and the Daily Overdue Inspection Digest. For other hazardous materials, see Chemical Storage inspections; for pressure vessels, see Air Receiver inspections.
The checklist references OSHA 29 CFR 1910.253(b) for cylinder marking, securing, valve caps, empty cylinders and oxygen separation, 1910.253(a)(4) and (e)(5) for regulators, hoses and connections, 1910.101(a) for visual inspection of cylinder condition, DOT 49 CFR 180.209 for requalification, and CGA P-1 and NFPA 55 for temperature limits. The Odiz App helps you document each check; it does not replace cylinder requalification or your gas supplier's handling instructions.

Spill kit inspection app for universal, oil-only, HazMat and mercury spill kits. The Odiz App records the kit …
Request quote
SKU ODIZ-15496

Chemical storage inspection app for cabinets, shelves, rooms and cages. The Odiz App checklist draws on OSHA 2…
Request quote
SKU ODIZ-15484

Eyewash station inspection app for plumbed and self-contained eyewash units. The Odiz App checks each station …
Request quote
SKU ODIZ-15488

Overhead and gantry crane inspection app for monthly documented crane inspections. Scan the crane’s QR tag and…
Request quote
SKU ODIZ-8002