Safety Through Innovation · Made in the USA

Chemical storage inspection app for cabinets, shelves, rooms and cages. The Odiz App checklist draws on OSHA 29 CFR 1910.1200, 1910.106 and 1910.1450: legible labels with hazard warnings, closed and intact containers, no leaks or spills, clear exits and separation of incompatible chemicals. Record the storage type and main chemical category, then inspect monthly.
Request information
OSHA's hazard communication and flammable liquids rules cover how hazardous chemicals are labeled and stored. The Odiz App checklist references these rules and defaults to a monthly inspection.
Hazard Communication Standard
Flammable Liquids
Laboratory Chemical Storage
Default Inspection Frequency
Problems that show up in chemical storage areas, and the checklist items that catch them.
Missing or Unreadable Labels
Containers with no label, faded or damaged labels, or labels without hazard warnings.
Open Containers
Lids and caps left off containers that are not being dispensed or used.
Leaks and Spills
Leaking or damaged containers, spilled product or standing liquid left in the storage area.
Incompatible Storage
Chemicals stored together when the label or SDS calls for separation, such as oxidizers beside flammable liquids.
Flammables Out of Place
Flammable liquids kept outside closed containers, safety cans, approved cabinets or approved storage areas.
Blocked Exits
Chemical storage placed in exits or stairways, or in front of emergency equipment and paths of safe passage.
Most chemical storage problems build up slowly: a label fades, a lid is left off, a new product is shelved next to something it reacts with. Each one is easy to miss on a busy day, and left alone it can lead to exposures, fires or spills.
OSHA’s Hazard Communication Standard, 29 CFR 1910.1200, requires labels or other forms of warning on hazardous chemical containers, and 1910.106 sets storage rules for flammable liquids. A monthly walk-through with a dated record shows what was checked at each location, what failed and how it was fixed.
Key criteria cited in the Chemical Storage checklist.
Labels and Other Forms of Warning
Hazardous chemical containers carry labels, tags or markings that identify the chemical and give hazard information, and the labels stay legible.
Incoming Container Labels
Labels on incoming containers of hazardous chemicals are not removed or defaced, including in laboratories and where chemicals are handled only in sealed containers.
Closed Containers and Spills
Where flammable liquids are used, containers are kept covered when not in use, and there is a means to dispose of leaks and spills promptly and safely.
Storage and Egress
Flammable liquids are not stored where they limit the use of exits, stairways or areas normally used for the safe passage of people.
A consistent way to inspect every chemical storage location on site and follow up on what fails.
Lookup by Tag or ID
Scan the QR tag on a cabinet, shelf or room, or enter its Equipment ID, to open its record and checklist.
Storage Details on Record
Storage type and primary chemical category are kept with each location.
Photos of Problems
Failed items require a photo, a description and a recommendation.
Tracked Fixes
Each failure becomes a corrective action with an assignee, a due date and a verification step.
Overdue Alerts
Upcoming and overdue inspections show on the To-Do list and in the Daily Overdue Inspection Digest.
PDF Reports
Every completed inspection produces a PDF report stored with the location's history.
Keep a dated history of every chemical storage inspection, with the inspector's name on each record.
Common questions about chemical storage inspections in the Odiz App.
It has 15 items covering container labels, closed and intact containers, leaks and spills, stable storage, flammable liquids, exits and egress, and separation of incompatible chemicals. Each item is answered Pass, Fail or N/A.
Label items reference 29 CFR 1910.1200(f) and (b), flammable liquid items reference 1910.106(d) and (e), and laboratory storage items reference Appendix A to 1910.1450.
No. The Chemical Storage checklist covers the storage location and its containers. Flammable storage cabinets have their own inspection in the Odiz App.
Chemical storage defaults to a monthly inspection, and the next due date follows that frequency after each submission. Inspections can be assigned to one or more people, and overdue ones appear in the To-Do list and the Daily Overdue Inspection Digest.
A failed item requires a photo, a description and a recommendation. The finding moves into Corrective Actions, where it gets an owner, a due date and a verification step before it closes.
Yes. The Odiz App includes a training module on chemical storage, and completions count toward each worker's training record.
Chemical storage areas change between inspections: containers get moved, labels fade, lids are left off and new products arrive without a planned spot. The Chemical Storage inspection in the Odiz App takes the inspector through 15 checks on labels, container condition, spills, flammable liquids, exits and compatibility, and records who inspected each location and when.
Add each storage location in the app and fix a QR tag to it. The add-equipment wizard asks for the manufacturer and model, and if that model is already in the shared catalog its details fill in automatically. At inspection time, open Equipment Lookup, scan the tag or enter the Equipment ID, and answer each item Pass, Fail or N/A. Inspections can be assigned to one or more people, and any assignee can complete them.
Each result is dated, recorded with the inspector's name and saved to the location's inspection history with a PDF report. The next due date follows the monthly default frequency. Failed items become findings in Corrective Actions with an owner, a due date and a verification step. For cabinet checks, see Flammable Storage Cabinet inspections; for SDS and labels, see Chemical Management (HazCom and SDS).
The checklist references OSHA 29 CFR 1910.1200 (Hazard Communication) for container labels and storage restrictions, 1910.1200(b)(3)(i) and (b)(4)(i) for incoming labels, 1910.106(d) and (e) for flammable liquid storage where flammables are present, 1910.106(d)(5)(i) for storage near exits and stairways, and Appendix A to 1910.1450 for laboratory storage. The Odiz App helps you document each check; it does not replace your hazard communication program or a review of each product's SDS.

Lifting sling inspection app for wire rope, alloy steel chain, synthetic web, round and metal mesh slings. Gro…
Request quote
SKU ODIZ-7992

Emergency shower inspection app for plumbed, self-contained and combination units. The Odiz App checks each sh…
Request quote
SKU ODIZ-15487

Pallet rack inspection app for racking and storage shelving. The Odiz App checks bent uprights, damaged beams,…
Request quote
SKU ODIZ-15495

Anchor point and lifeline inspection app for fall arrest anchors, horizontal and vertical lifelines and self-r…
Request quote
SKU ODIZ-15483