Safety Through Innovation · Made in the USA

Air receiver inspection app for compressed air tanks and pressure vessels. The Odiz App checks each receiver against OSHA 29 CFR 1910.169: an accessible location, a readily visible pressure gauge, spring-loaded safety valves, no valve between the receiver and its safety valves, a drain valve at the lowest point and frequent draining. Inspections default to monthly.
Request information
OSHA's compressed air receiver standard covers installation, drains, gauges and safety valves, and points to the ASME pressure vessel code for construction. The Odiz App checklist references both and defaults to a monthly inspection.
OSHA Air Receiver Standard
Pressure Vessel Construction
Gauges and Safety Valves
Default Inspection Frequency
Problems that show up on compressed air receivers, and the checklist items that catch them.
Missing or Hidden Gauge
No indicating pressure gauge, or a gauge mounted where it cannot be readily seen.
Valve Before the Safety Valve
A shutoff or other valve installed between the receiver and its safety valve, which can isolate the protection.
Receiver Not Drained
Oil and water left to build up because the drain valve is not opened often enough.
Inaccessible Receiver
Tanks buried, boxed in or placed where drains, handholes and manholes cannot be easily reached.
Bypassed Safety Devices
Safety valves or other safety devices that have been modified, plugged, blocked or disabled.
Shell Damage and Leaks
Visible defects on the shell, heads, seams or supports, and air, oil or condensate leaks at fittings, valves and drains.
An air receiver holds a large volume of compressed air, and that stored energy is released all at once if the vessel or its fittings fail. A working pressure gauge, a safety valve that cannot be isolated and a drain that gets used are the basic protections. Condensate left in the tank also reduces usable volume and can corrode the shell from the inside.
OSHA 1910.169(b)(3) requires an indicating pressure gauge and one or more spring-loaded safety valves with enough relieving capacity to keep pressure from exceeding the maximum allowable working pressure by more than 10 percent, and 1910.169(b)(2) requires the receiver to be drained often enough to prevent excessive liquid buildup. A monthly inspection in the Odiz App gives each receiver a dated record of these checks.
Key requirements cited in the Air Receiver / Compressed Air Pressure Vessel checklist.
ASME Construction
New air receivers installed after August 27, 1971 are constructed in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII.
Installation
Receivers are installed so that all drains, handholes and manholes are easily accessible. A receiver is never buried underground or located in an inaccessible place.
Drains and Traps
A drain pipe and valve at the lowest point removes accumulated oil and water. Automatic traps may be installed in addition to the drain valve, and the receiver is drained often enough to prevent excessive liquid buildup.
Gauges and Safety Valves
Every receiver has a readily visible indicating pressure gauge and one or more spring-loaded safety valves that keep pressure from exceeding the maximum allowable working pressure by more than 10 percent. No valve of any type is placed between the receiver and its safety valves.
A consistent monthly routine for every receiver on site, with follow-up on what fails.
QR Tag per Receiver
Scan the tag in Equipment Lookup, or enter the Equipment ID, to open the receiver's record and checklist.
Catalog Auto-Fill
The add-equipment wizard fills in model details from a shared catalog when that model has been added before.
MAWP on Record
Maximum allowable working pressure, capacity and orientation are stored with each receiver for comparison at every inspection.
Photos of Defects
Failed items require a photo, a description and a recommendation.
Tracked Fixes
Each failure becomes a corrective action with an assignee, a due date and a verification step.
Pass Rates in Analytics
Analytics shows submissions, pass rate, failures by equipment type and overdue items, including air receivers.
Keep a dated history of every air receiver inspection, with the inspector's name and a PDF report for each one.
Common questions about compressed air receiver inspections in the Odiz App.
29 CFR 1910.169(b)(3) requires an indicating pressure gauge located so it is readily visible and one or more spring-loaded safety valves, with no valve of any type between the receiver and its safety valves. The checklist covers each of these as a separate item.
1910.169(b)(2) does not set a fixed interval. It requires the receiver to be drained frequently enough to prevent excessive liquid buildup, and automatic traps are allowed in addition to the drain valve, not in place of it.
Under 1910.169(b)(3)(i), the total relieving capacity of the safety valves must keep receiver pressure from exceeding the maximum allowable working pressure by more than 10 percent. The app stores the MAWP for each receiver and includes an item comparing it with the pressure seen at inspection.
Air receivers default to a monthly inspection, and the next due date is set after each submission. Receivers can be assigned to one or more people, and overdue ones appear in the To-Do list and the Daily Overdue Inspection Digest.
No. The Odiz App helps you document routine visual checks against 1910.169. It does not replace safety valve testing, internal inspections or inspections required by your jurisdiction or insurer.
Yes. The Odiz App includes a built-in training module on air receivers, and completions are added to each worker's training record.
An air receiver stores compressed air under pressure, and its safety depends on a readable gauge, a safety valve that cannot be isolated and a drain valve that is opened often enough to keep liquid from building up. These checks are simple and easy to overlook. The Air Receiver / Compressed Air Pressure Vessel inspection in the Odiz App walks through the OSHA 29 CFR 1910.169 items each month and records who inspected each receiver and when.
Add each receiver with the add-equipment wizard: enter the manufacturer and model, and if that model is already in the shared catalog its details fill in automatically. Fix a QR tag to the tank or its support. At inspection time, scan the tag in Equipment Lookup or enter the Equipment ID, read the gauge, look over the valves, drain and shell, and answer each item Pass, Fail or N/A. The automatic trap item, for example, is marked N/A where no trap is installed.
The result is dated, recorded with the inspector's name and saved to the receiver's history with a PDF report, and the next due date follows the monthly default. Inspections can be assigned to one or more people, and receivers past due appear in each assignee's To-Do list and in the Daily Overdue Inspection Digest. For gas cylinders stored on site, see Compressed Gas Cylinder inspections; to follow findings through to closure, see Corrective Action Management.
The checklist references OSHA 29 CFR 1910.169, which covers compressed air receivers used for operations such as cleaning, drilling, hoisting and chipping. Items cite 1910.169(b)(1) for installation, 1910.169(b)(2) for drains and traps, 1910.169(b)(3) for gauges and safety valves, and 1910.169(a)(2)(i) for construction to the ASME Boiler and Pressure Vessel Code, Section VIII. The Odiz App helps you document each visual check; it does not replace safety valve testing or any internal or jurisdictional pressure vessel inspection your site requires.

Rolling scaffold inspection app for rolling scaffolds and mobile scaffold towers. Record tower type, platform …
Request quote
SKU ODIZ-7974

Emergency lighting inspection app for emergency lights, exit signs and combination units. Scan each unit’s QR …
Request quote
SKU ODIZ-7996

Chemical storage inspection app for cabinets, shelves, rooms and cages. The Odiz App checklist draws on OSHA 2…
Request quote
SKU ODIZ-15484

Pallet rack inspection app for racking and storage shelving. The Odiz App checks bent uprights, damaged beams,…
Request quote
SKU ODIZ-15495