Safety Through Innovation · Made in the USA

Guardrail and handrail inspection app for platforms, mezzanines and stairways. The Odiz App checks rails against OSHA 29 CFR 1910.29: top rail height of 42 inches plus or minus 3 inches, midrails, toeboards, load capacity, handrail height and clearance, and damage. Record the system type and rail details once, then inspect monthly.
Request information
OSHA's walking-working surfaces rules set where fall protection is needed and how guardrails and handrails are built. The Odiz App checklist references these rules and defaults to a monthly inspection.
Fall Protection Systems Criteria
Duty to Have Fall Protection
Handrails and Stair Rails
Default Inspection Frequency
Problems that show up on guardrail and handrail systems, and the checklist items that catch them.
Wrong Top Rail Height
Top rails outside 42 inches, plus or minus 3 inches, above the walking-working surface.
Missing Midrails
No midrail, screen or intermediate members between the top rail and the surface, leaving openings a person can fall through.
No Toeboards
Open edges above work areas without toeboards where people below are exposed to falling objects.
Loose Posts and Connections
Loose fasteners, cracks or corroded posts that reduce the strength of the system.
Removed Sections
Rail sections cut, lowered or taken out for equipment access without alternate protection in place.
Handrail Defects
Handrails outside 30 to 38 inches, with obstructions on the graspable surface or too little clearance from the wall.
Guardrails are passive protection: workers rely on them without thinking about it. A rail that has been struck, cut, lowered or loosened can fail at the moment someone leans on it or stumbles into it.
OSHA 1910.28(b)(1) requires protection at unprotected sides and edges 4 feet or more above a lower level. Regular inspections help confirm that guardrail protection is still in place and still meets the 1910.29 criteria, and a dated record shows when each system was last checked.
Key criteria cited in the Guardrails and Handrails checklist.
Top Rail Height
The top edge of a guardrail system is 42 inches, plus or minus 3 inches, above the walking-working surface.
Strength
Top rails withstand at least 200 pounds applied outward or downward. Midrails, screens, mesh and other intermediate members withstand at least 150 pounds.
Handrails and Stair Rail Systems
Covers handrail and stair rail height, graspability and clearance, with handrails 30 to 38 inches above the leading edge of the stair tread and at least 2.25 inches from walls.
Toeboards
Where toeboards protect workers below from falling objects, they are at least 3.5 inches high.
A consistent way to inspect every rail run on site and follow up on what fails.
QR Tags per Rail Run
Scan the tag on each guardrail or stairway to open its record and checklist.
Measurements on Record
Guarded surface height and rail height are stored with each system for comparison.
Photos of Defects
Failed items require a photo, a description and a recommendation.
Tracked Fixes
Each failure becomes a corrective action with an assignee, a due date and a verification step.
Due Date Reminders
Upcoming and overdue rail inspections show on the To-Do list, and the Inspection Overdue email flags misses.
Pass Rates in Analytics
Analytics shows submissions, pass rate and failures by equipment type, including guardrails and handrails.
Keep a dated history of every guardrail and handrail inspection in one place.
Common questions about guardrail and handrail inspections in the Odiz App.
29 CFR 1910.29(b)(1) sets the top edge of a guardrail system at 42 inches, plus or minus 3 inches, above the walking-working surface. The Odiz App checks this as its first item.
Under 1910.29(b)(2), midrails, screens, mesh or other intermediate members fill the space between the top rail and the walking-working surface. The checklist confirms midrails sit about halfway up and intermediate members leave openings of no more than 19 inches.
Yes. The System Type field covers guardrails on open-sided platforms and mezzanines, handrails along stairs and stair rail systems. Handrail items check height, graspability and wall clearance under 1910.29(f).
Guardrails and handrails default to a monthly inspection, and the next due date resets after each submission. Inspecting sooner after an impact or repair is a good practice.
The checklist includes an item for unauthorized modifications such as cutting, lowering or removing sections without alternate protection. A fail requires a photo, a description and a recommendation and creates a corrective action with an owner and a due date.
Yes. The Odiz App includes a read-and-sign training module on guardrails and handrails, and signed completions are added to each worker's training record.
Guardrails and handrails get struck by equipment, cut for machinery moves and loosened by vibration, and the damage is not always obvious from the floor. The Guardrails & Handrails inspection in the Odiz App checks each system against the height, opening and strength criteria in OSHA 29 CFR 1910.29 and records who inspected it and when.
Fix a QR tag to each guardrail run or stairway and add it in the app with its system type and measurements. At inspection time, scan the tag in Equipment Lookup, measure and look over the rails, and answer each item Pass, Fail or N/A. Items such as the wood or cable guardrail checks can be marked N/A where they do not apply.
The dated result is saved to the system's history with a PDF report. Failed items create findings in Corrective Actions with an owner and a due date. For portable access equipment, see Mobile Stair and Platform inspections; for personal fall arrest anchorages, see Anchor Point and Lifeline inspections.
The checklist references OSHA 29 CFR 1910.29(b) for guardrail height, midrails, strength and surfaces, 1910.29(f) for handrails and stair rail systems, 1910.29(k) for toeboards, and 1910.28(b)(1) for protection at unprotected sides and edges. The Odiz App helps you document each check; it does not replace an engineering assessment of rail strength.

Aerial lift inspection app for daily pre-use checks of boom lifts, bucket trucks and other man lifts. The Odiz…
Request quote
SKU ODIZ-15481

Pallet rack inspection app for racking and storage shelving. The Odiz App checks bent uprights, damaged beams,…
Request quote
SKU ODIZ-15495

Chemical storage inspection app for cabinets, shelves, rooms and cages. The Odiz App checklist draws on OSHA 2…
Request quote
SKU ODIZ-15484

Eyewash station inspection app for plumbed and self-contained eyewash units. The Odiz App checks each station …
Request quote
SKU ODIZ-15488