Safety Through Innovation · Made in the USA

First aid kit inspection app for wall cabinets and portable kits. The Odiz App checks each kit against OSHA 29 CFR 1910.151(b): readily available and unblocked, clearly identified, intact, stocked in adequate quantity, free of damaged, unsealed or expired supplies, with bloodborne pathogen PPE where needed. Results are dated, and the next check is due monthly.
Request information
OSHA requires adequate first aid supplies to be readily available at the workplace. The Odiz App checklist references these rules and defaults to a monthly inspection.
First Aid Supplies
First Aid Kit Contents
Bloodborne Pathogen PPE
Default Inspection Frequency
Problems found at first aid kits and cabinets, and the checklist items that catch them.
Depleted Kits
Supplies used up and not replaced, leaving too little to treat the injuries the kit is meant for.
Expired Supplies
Ointments, wipes, eyewash solution or other dated items kept past their expiration date.
Opened Sterile Packs
Sterile dressings and pads with torn or opened packaging where sterility matters.
Blocked or Locked Kits
Kits behind locked doors, hidden in offices or blocked by stored materials, delaying access.
Damaged Kit or Contents
Cracked cases, broken latches or contents that are wet, dirty, leaking or otherwise unusable.
Missing PPE for Blood Exposure
No gloves or other protective equipment where giving first aid can involve contact with blood or other potentially infectious materials.
First aid kits are used in small amounts and restocked rarely, so the gap between a full kit and what is actually inside grows quietly. When someone is cut or burned, the people helping need the right supplies, in usable condition, within reach.
OSHA 1910.151(b) requires adequate first aid supplies to be readily available. A regular, dated inspection helps confirm each kit is stocked, sealed and in date, and the record shows when it was last checked, by whom and which failed items were followed up in Corrective Actions.
Key requirements cited in the First Aid Kit checklist.
Trained Responders and Supplies
In the absence of an infirmary, clinic or hospital in near proximity used to treat all injured employees, a person or persons must be adequately trained to render first aid, and adequate first aid supplies must be readily available.
Kit Contents
This non-mandatory appendix points to ANSI Z308.1 as an example of minimally acceptable kit contents and advises employers to assess their specific needs and add supplies for unique or changing hazards.
Personal Protective Equipment
When there is occupational exposure to blood or other potentially infectious materials, the employer provides appropriate PPE such as gloves, face shields or masks, eye protection and resuscitation mouthpieces or pocket masks.
Adequate Quantity
The checklist cites a February 2007 OSHA standard interpretation for its adequate quantity item, which asks whether supplies fit the kit's intended workplace use.
A consistent way to inspect every first aid kit on site and follow up on what fails.
QR Tag on Each Kit
Scan the tag or enter the Equipment ID in Equipment Lookup to open the kit's record and checklist.
Catalog Auto-Fill
Enter the manufacturer and model, and details for a model added before fill in from a shared catalog.
Photos of Missing Items
Failed items require a photo, a description and a recommendation, so it is clear what needs restocking or replacing.
Tracked Restocks
Each failure becomes a corrective action with an assignee, a due date and a verification step before it closes.
Shared Assignments
Assign a kit's inspection to one or more people, and any assignee can complete it.
Pass Rates in Analytics
Analytics shows submissions, pass rate and failures by equipment type, including first aid kits.
Keep a dated history of every first aid kit inspection, with the inspector's name and a PDF report on each record.
Common questions about first aid kit inspections in the Odiz App.
29 CFR 1910.151(b) requires adequate first aid supplies to be readily available. The rule does not set a single required contents list; non-mandatory Appendix A points to ANSI Z308.1 as an example of minimum contents.
First aid kits default to a monthly inspection, and the next due date is set from that frequency after each submission. An inspection can also be started at any time from Equipment Lookup, for example after a kit has been used.
Yes. One item checks that no expired supplies are present where expiration dates are listed, and another checks that sterile or sealed supplies remain sealed where sterility is necessary.
Where first aid response can reasonably involve blood or other potentially infectious materials, Appendix A to 1910.151 points to the PPE requirements of 29 CFR 1910.1030(d)(3). The checklist includes an item for this additional PPE.
A failed item requires a photo, a description and a recommendation, and it flows into Corrective Actions as a finding with an assignee and a due date. The finding stays open until the fix is verified.
Yes. The Odiz App includes a read-and-sign training module on first aid kits, and completed modules are added to each worker's training record. First aid courses and their expiration dates can be tracked in Training Records and Qualifications.
First aid kits get used a little at a time: a few bandages here, a pair of gloves there, and nobody restocks until the kit is needed and found empty. The First Aid Kit inspection in the Odiz App checks each kit or cabinet against the requirement in OSHA 29 CFR 1910.151(b) that adequate first aid supplies be readily available, and records who inspected it and when.
Add each kit with the add-equipment wizard: enter the manufacturer and model, and if that model has been added before, its details auto-fill from a shared catalog. Fix a QR tag to the kit or cabinet. At inspection time, scan the tag or enter the Equipment ID in Equipment Lookup, open the kit and answer each item Pass, Fail or N/A. Inspections can be assigned to one or more people, such as the first aid responders in each area.
The result is dated, recorded with the inspector's name and saved to the kit's inspection history with a PDF report, and the next due date is set from the monthly default frequency. A failed item, such as missing gauze or expired supplies, becomes a finding in Corrective Actions with an assignee, a due date and a verification step. First aid cases can be logged in Incident and Near Miss Reporting, and nearby flushing equipment can be checked with Eyewash Station inspections.
The checklist references OSHA 29 CFR 1910.151(b), which requires adequate first aid supplies to be readily available, along with an OSHA standard interpretation on adequate quantity. Non-mandatory Appendix A to 1910.151 points to ANSI Z308.1 as an example of minimum kit contents and notes that employers with unique or changing first aid needs may need to add supplies. Where first aid can reasonably involve exposure to blood or other potentially infectious materials, the checklist also references the PPE provisions of 29 CFR 1910.1030(d)(3). The Odiz App helps you document each check; it does not decide what your kits must contain.

Guardrail and handrail inspection app for platforms, mezzanines and stairways. The Odiz App checks rails again…
Request quote
SKU ODIZ-15493

Emergency lighting inspection app for emergency lights, exit signs and combination units. Scan each unit’s QR …
Request quote
SKU ODIZ-7996

Lifting sling inspection app for wire rope, alloy steel chain, synthetic web, round and metal mesh slings. Gro…
Request quote
SKU ODIZ-7992

Full body harness inspection app for monthly, documented harness checks. Tag each storage location with a QR c…
Request quote
SKU ODIZ-7979