Safety Through Innovation · Made in the USA

574.318.4333Email UsODIZ AI Login
OdizSafety
ProductsServicesOdiz AICompany
Get an AssessmentGet an Assessment

Start a project

Let’s engineer a safer floor.

Schedule an AssessmentSchedule an Assessment
574-318-4333info@odiz.com
Odiz — Safety Through Innovation. Made in the USA.

Industrial safety, engineered from assessment through sustained compliance. Based in South Bend, serving manufacturers across North America.

Appearance

Solutions

  • Machine Safety
  • EHS Compliance
  • Laser Safety
  • Safety Software

Services

  • Machine Guarding Risk Assessment
  • Engineering & Design
  • Validation
  • All Services

Products

  • Machining
  • Metal Forming
  • Electronic Safety Enclosures
  • Accessories
  • All Products

Company

  • About Us
  • Resources
  • OSHA & ANSI Standards
  • Request a Quote
  • Contact
  • My Account

© 2026 Odiz Safety LLC. All rights reserved.

DUNS 080380452CAGE 7PX28
PrivacyTermsReturnsSafety Through Innovation

ODIZ

  1. Products
  2. /Services
  3. /Software and Apps
  4. /Inspection Apps
  5. /OSHA Respirator Inspections (Filtering Facepiece)
OSHA Respirator Inspections (Filtering Facepiece)
Inspection Apps

OSHA Respirator Inspections (Filtering Facepiece)

SKU ODIZ-15489

Filtering facepiece respirator inspection app for dust masks and N95-class respirators. The Odiz App records the NIOSH approval number, filter rating, lot number and expiration date, then checks condition, alterations, shelf life and storage against OSHA 29 CFR 1910.134. Damaged or expired stock is flagged and tracked until it is removed.

Request a quoteIn stock

Request information

Name *
Inspection Apps

Respirator Rules to Know

OSHA's respiratory protection standard covers selection, storage, inspection and removal of defective respirators. The Odiz App checklist references these rules and defaults to a monthly inspection.

29 CFR 1910.134

Respiratory Protection Standard

1910.134(h)

Maintenance and Care

42 CFR Part 84

NIOSH Respirator Approval

Monthly

Default Inspection Frequency

Common Respirator Violations

Problems found with filtering facepiece supplies, each covered by an item in the Odiz App checklist.

🏷️

Unidentified Respirators

Respirators with no legible manufacturer, model, filter rating or NIOSH approval marking.

😷

Damaged Units

Tears, punctures, crushed facepieces, broken straps or damaged nosepieces and valves.

✂️

Altered Respirators

Respirators cut, taped, stapled or otherwise modified from their approved condition.

⌛

Expired Stock

Units past the manufacturer expiration date still available for use.

☀️

Poor Storage

Respirators stored where they are exposed to dust, sunlight, extreme temperatures, moisture or damaging chemicals.

🚫

Defective Units Left in Stock

Damaged, contaminated or expired respirators not removed from available stock or marked out of service.

Why Respirator Inspections Matter

A filtering facepiece respirator protects the wearer only when it has the right rating, is within its shelf life and is in its approved condition. Crushed, contaminated or altered respirators may not filter or seal as designed, and a damaged unit handed out at the start of a shift may be worn all day.

OSHA 1910.134(h) requires respirators to be stored to protect them from damage and contamination, and defective respirators to be removed from service. A monthly check of each supply catches problems before units are handed out, and the record shows what was found and fixed.

Respiratory Protection References

Requirements cited in the Respiratory Protection checklist, plus the federal approval rule behind filter ratings.

1910.134(d)(1)(ii)

NIOSH-Certified Respirators

The employer selects a NIOSH-certified respirator, used in compliance with the conditions of its certification.

1910.134(h)(2)(i)

Storage

Respirators are stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture and damaging chemicals, and packed or stored to prevent deformation of the facepiece.

1910.134(h)(3) and (h)(4)

Inspection and Removal

Respirators are inspected for function and condition, and respirators that fail an inspection or are found defective are removed from service.

42 CFR Part 84

Respirator Certification

The NIOSH approval regulation that defines filter classes such as N95, R95 and P100 and the approval markings found on certified respirators.

How the Odiz App Helps

Simple monthly checks for respirator supplies wherever they are stored.

🔍

Approval Data on File

NIOSH approval number, filter rating, lot number and expiration date stay with each supply.

📱

QR Lookup

Scan a tag or enter the Equipment ID to open the right supply and its checklist.

📸

Photos on Failure

A failed item requires a photo, a description and a recommendation.

🔁

Scan Another

After submitting, move straight to the next tagged supply.

✅

Corrective Actions

Replacements and storage fixes are assigned with due dates and verified before closing.

⏰

Overdue Alerts

Missed monthly checks appear on the To-Do list and in the daily overdue digest.

Keep a monthly record of the condition and storage of every respirator supply on site.

Filtering Facepiece Respirator FAQs

Common questions about inspecting dust masks and filtering facepiece respirators with the Odiz App.

+−What is a filtering facepiece respirator?

It is a disposable respirator in which the facepiece itself is the filter, such as an N95. The Odiz App lists filter ratings N95, N99, N100, R95, R99, R100, P95, P99 and P100.

+−What does OSHA require for respirator storage?

29 CFR 1910.134(h)(2)(i) requires respirators to be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture and damaging chemicals. The checklist has a dedicated storage item.

+−Does the checklist track expiration dates?

Yes. The expiration date is recorded with each supply, and a checklist item confirms respirators are within the manufacturer expiration date where one is listed.

+−Does this replace fit testing?

No. Fit testing and medical evaluation are separate requirements of 1910.134. This checklist covers identification, condition, alteration, expiration and storage of the respirators themselves.

+−How often are respirator supplies inspected in the app?

This equipment type defaults to a monthly inspection, with the next due date set on each submission. Separately, 1910.134(h)(3) calls for respirators used in routine situations to be inspected before each use.

+−Is respirator training included?

The Odiz App includes a read-and-sign respiratory protection training module, and signed completions count toward each worker's training record.

Filtering facepiece respirators are often handed out from a box on a shelf, which makes it easy for damaged, contaminated or expired units to reach a worker. OSHA 29 CFR 1910.134 requires respirators to be NIOSH-certified, stored to protect them from damage and contamination, and removed from service when defective. The Respiratory Protection (Dust Masks / Filtering Facepiece Respirators) inspection in the Odiz App gives each tagged respirator supply an 8-item monthly check and a dated record of the results.

Key features

  • Approval details: record the NIOSH approval or TC number, filter rating (N, R or P series at 95, 99 or 100), lot number and expiration date for each supply.
  • Identification checks: confirm the respirator is identifiable by manufacturer, model and filter rating, and that the NIOSH approval marking is legible.
  • Condition checks: look for tears, punctures, crushing, broken straps, a damaged nosepiece or valve, and any cutting, taping or stapling that alters the approved condition.
  • Expiration and storage: flag units past the manufacturer expiration date and storage that exposes respirators to dust, sunlight, extreme temperatures, moisture or damaging chemicals.
  • Removal from stock: the last item confirms defective, contaminated or expired respirators are removed from available stock or marked out of service.
  • Photo-backed failures: each failed item needs a photo, a description and a recommendation, and opens a corrective action with an owner and a due date.
  • Scan and go: scan the QR tag on a cabinet, dispenser or box in Equipment Lookup, and after submitting choose to scan the next one.

How it works

Add each respirator supply with its approval number, filter rating, lot number and expiration date. Each month, the inspector scans its QR tag or enters the Equipment ID, marks each item Pass, Fail or N/A, and signs. The result is saved to the item's history with a PDF report.

Failures go to Corrective Actions for replacement or relocation of stock and stay open until verified. Overdue checks show on the To-Do list and in the Daily Overdue Inspection Digest. To measure the exposures behind respirator selection, see Industrial Hygiene Exposure Monitoring.

Standards

The checklist references OSHA 29 CFR 1910.134(d)(1)(ii) for NIOSH-certified respirators used within their certification, 1910.134(h)(1) and (h)(2) for cleanliness and storage, and 1910.134(h)(3) and (h)(4) for inspection and removal of defective respirators. Filter ratings such as N95 and P100 are NIOSH certification classes under 42 CFR Part 84. Fit testing and medical evaluation are separate parts of 1910.134 and are not covered by this checklist.

Write a review

Related products

OSHA Pallet Rack & Storage Shelving Inspections
Inspection Apps

OSHA Pallet Rack & Storage Shelving Inspections

Pallet rack inspection app for racking and storage shelving. The Odiz App checks bent uprights, damaged beams,…

Request quote

SKU ODIZ-15495

View →
OSHA Rolling Scaffold Inspections
Inspection Apps

OSHA Rolling Scaffold Inspections

Rolling scaffold inspection app for rolling scaffolds and mobile scaffold towers. Record tower type, platform …

Request quote

SKU ODIZ-7974

View →
OSHA Emergency Lighting Inspections
Inspection Apps

OSHA Emergency Lighting Inspections

Emergency lighting inspection app for emergency lights, exit signs and combination units. Scan each unit’s QR …

Request quote

SKU ODIZ-7996

View →
OSHA Anchor Point & Lifeline Inspections
Inspection Apps

OSHA Anchor Point & Lifeline Inspections

Anchor point and lifeline inspection app for fall arrest anchors, horizontal and vertical lifelines and self-r…

Request quote

SKU ODIZ-15483

View →