Safety Through Innovation · Made in the USA

Filtering facepiece respirator inspection app for dust masks and N95-class respirators. The Odiz App records the NIOSH approval number, filter rating, lot number and expiration date, then checks condition, alterations, shelf life and storage against OSHA 29 CFR 1910.134. Damaged or expired stock is flagged and tracked until it is removed.
Request information
OSHA's respiratory protection standard covers selection, storage, inspection and removal of defective respirators. The Odiz App checklist references these rules and defaults to a monthly inspection.
Respiratory Protection Standard
Maintenance and Care
NIOSH Respirator Approval
Default Inspection Frequency
Problems found with filtering facepiece supplies, each covered by an item in the Odiz App checklist.
Unidentified Respirators
Respirators with no legible manufacturer, model, filter rating or NIOSH approval marking.
Damaged Units
Tears, punctures, crushed facepieces, broken straps or damaged nosepieces and valves.
Altered Respirators
Respirators cut, taped, stapled or otherwise modified from their approved condition.
Expired Stock
Units past the manufacturer expiration date still available for use.
Poor Storage
Respirators stored where they are exposed to dust, sunlight, extreme temperatures, moisture or damaging chemicals.
Defective Units Left in Stock
Damaged, contaminated or expired respirators not removed from available stock or marked out of service.
A filtering facepiece respirator protects the wearer only when it has the right rating, is within its shelf life and is in its approved condition. Crushed, contaminated or altered respirators may not filter or seal as designed, and a damaged unit handed out at the start of a shift may be worn all day.
OSHA 1910.134(h) requires respirators to be stored to protect them from damage and contamination, and defective respirators to be removed from service. A monthly check of each supply catches problems before units are handed out, and the record shows what was found and fixed.
Requirements cited in the Respiratory Protection checklist, plus the federal approval rule behind filter ratings.
NIOSH-Certified Respirators
The employer selects a NIOSH-certified respirator, used in compliance with the conditions of its certification.
Storage
Respirators are stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture and damaging chemicals, and packed or stored to prevent deformation of the facepiece.
Inspection and Removal
Respirators are inspected for function and condition, and respirators that fail an inspection or are found defective are removed from service.
Respirator Certification
The NIOSH approval regulation that defines filter classes such as N95, R95 and P100 and the approval markings found on certified respirators.
Simple monthly checks for respirator supplies wherever they are stored.
Approval Data on File
NIOSH approval number, filter rating, lot number and expiration date stay with each supply.
QR Lookup
Scan a tag or enter the Equipment ID to open the right supply and its checklist.
Photos on Failure
A failed item requires a photo, a description and a recommendation.
Scan Another
After submitting, move straight to the next tagged supply.
Corrective Actions
Replacements and storage fixes are assigned with due dates and verified before closing.
Overdue Alerts
Missed monthly checks appear on the To-Do list and in the daily overdue digest.
Keep a monthly record of the condition and storage of every respirator supply on site.
Common questions about inspecting dust masks and filtering facepiece respirators with the Odiz App.
It is a disposable respirator in which the facepiece itself is the filter, such as an N95. The Odiz App lists filter ratings N95, N99, N100, R95, R99, R100, P95, P99 and P100.
29 CFR 1910.134(h)(2)(i) requires respirators to be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture and damaging chemicals. The checklist has a dedicated storage item.
Yes. The expiration date is recorded with each supply, and a checklist item confirms respirators are within the manufacturer expiration date where one is listed.
No. Fit testing and medical evaluation are separate requirements of 1910.134. This checklist covers identification, condition, alteration, expiration and storage of the respirators themselves.
This equipment type defaults to a monthly inspection, with the next due date set on each submission. Separately, 1910.134(h)(3) calls for respirators used in routine situations to be inspected before each use.
The Odiz App includes a read-and-sign respiratory protection training module, and signed completions count toward each worker's training record.
Filtering facepiece respirators are often handed out from a box on a shelf, which makes it easy for damaged, contaminated or expired units to reach a worker. OSHA 29 CFR 1910.134 requires respirators to be NIOSH-certified, stored to protect them from damage and contamination, and removed from service when defective. The Respiratory Protection (Dust Masks / Filtering Facepiece Respirators) inspection in the Odiz App gives each tagged respirator supply an 8-item monthly check and a dated record of the results.
Add each respirator supply with its approval number, filter rating, lot number and expiration date. Each month, the inspector scans its QR tag or enters the Equipment ID, marks each item Pass, Fail or N/A, and signs. The result is saved to the item's history with a PDF report.
Failures go to Corrective Actions for replacement or relocation of stock and stay open until verified. Overdue checks show on the To-Do list and in the Daily Overdue Inspection Digest. To measure the exposures behind respirator selection, see Industrial Hygiene Exposure Monitoring.
The checklist references OSHA 29 CFR 1910.134(d)(1)(ii) for NIOSH-certified respirators used within their certification, 1910.134(h)(1) and (h)(2) for cleanliness and storage, and 1910.134(h)(3) and (h)(4) for inspection and removal of defective respirators. Filter ratings such as N95 and P100 are NIOSH certification classes under 42 CFR Part 84. Fit testing and medical evaluation are separate parts of 1910.134 and are not covered by this checklist.

Pallet rack inspection app for racking and storage shelving. The Odiz App checks bent uprights, damaged beams,…
Request quote
SKU ODIZ-15495

Rolling scaffold inspection app for rolling scaffolds and mobile scaffold towers. Record tower type, platform …
Request quote
SKU ODIZ-7974

Emergency lighting inspection app for emergency lights, exit signs and combination units. Scan each unit’s QR …
Request quote
SKU ODIZ-7996

Anchor point and lifeline inspection app for fall arrest anchors, horizontal and vertical lifelines and self-r…
Request quote
SKU ODIZ-15483