Safety Through Innovation · Made in the USA

574.318.4333Email UsODIZ AI Login
OdizSafety
ProductsServicesOdiz AICompany
Get an AssessmentGet an Assessment

Start a project

Let’s engineer a safer floor.

Schedule an AssessmentSchedule an Assessment
574-318-4333info@odiz.com
Odiz — Safety Through Innovation. Made in the USA.

Industrial safety, engineered from assessment through sustained compliance. Based in South Bend, serving manufacturers across North America.

Appearance

Solutions

  • Machine Safety
  • EHS Compliance
  • Laser Safety
  • Safety Software

Services

  • Machine Guarding Risk Assessment
  • Engineering & Design
  • Validation
  • All Services

Products

  • Machining
  • Metal Forming
  • Electronic Safety Enclosures
  • Accessories
  • All Products

Company

  • About Us
  • Resources
  • OSHA & ANSI Standards
  • Request a Quote
  • Contact
  • My Account

© 2026 Odiz Safety LLC. All rights reserved.

DUNS 080380452CAGE 7PX28
PrivacyTermsReturnsSafety Through Innovation

ODIZ

  1. Products
  2. /Services
  3. /Software and Apps
  4. /EHS Management Apps
  5. /Industrial Hygiene Exposure Monitoring
Industrial Hygiene Exposure Monitoring
EHS Management Apps

Industrial Hygiene Exposure Monitoring

SKU ODIZ-15478

Industrial hygiene exposure monitoring app for air, noise, surface, biological and ventilation surveys. The Odiz App checks each result against its OSHA limit, sends hazardous results to Corrective Actions when the survey is signed off, puts every re-survey date on the calendar and in reminder emails, and prints results letters for the people sampled.

Request a quoteIn stock

Request information

Name *
EHS Management Apps

OSHA Exposure Monitoring Standards

Each survey type in the Odiz App cites the OSHA rules and guidance behind it. These are the core standards.

29 CFR 1910.1000

Air Contaminant Limits

29 CFR 1910.1001-1053

Substance-Specific Standards

29 CFR 1910.95

Occupational Noise Exposure

29 CFR 1910.134(f)(2)

Respirator Fit Testing

Common Exposure Monitoring Violations

Typical monitoring and recordkeeping gaps that leave overexposures undetected or undocumented.

🧪

No Exposure Assessment

Exposures never measured for a substance with its own standard, such as silica or lead, so nobody knows whether the action level or PEL is exceeded.

📅

Missed Periodic Monitoring

Results at or above the action level not repeated on schedule, for example every 6 months for silica and lead, or every 3 months above the PEL.

📨

Late Employee Notification

Monitoring results not given to the affected employees within the 15 working days that most substance-specific standards allow.

🔊

Noise Program Gaps

No noise monitoring where exposures may reach the 85 dBA action level, or no annual audiograms for employees in the hearing conservation program.

😷

Respirators Without Exposure Data

Respirators selected without a reasonable estimate of exposure, as 1910.134(d)(1)(iii) requires, or fit tests not repeated at least annually.

🗄️

Lost Exposure Records

Exposure records, including air sampling and biological monitoring results, not kept for at least 30 years as 1910.1020 requires.

Why Exposure Monitoring Matters

Hearing loss, silicosis and lead poisoning develop over years of exposure that workers often cannot see or feel. Measured results show whether controls are working and whether respirators, hearing protection or medical surveillance are needed.

OSHA’s substance-specific standards tie monitoring frequency, employee notification and record retention to the results. A result at or above the action level can start a schedule that repeats every 3 or 6 months until two consecutive results are below the action level.

The Odiz App keeps each survey, its results, its findings and its next due date together, so overdue re-surveys and late notices are visible before they become gaps.

OSHA Rules Behind Each Survey

The citations below come from the regulatory guide built into the Industrial Hygiene tool.

29 CFR 1910.1000

Air Contaminants

Tables Z-1, Z-2 and Z-3 set 8-hour TWA, ceiling and peak limits. For mixtures, the sum of each concentration divided by its limit must not exceed 1.

29 CFR 1910.1001-1053

Substance-Specific Standards

Add action levels, periodic monitoring and 15-working-day employee notification. Silica (1910.1053(d)(3)) and lead (1910.1025(d)(6)) are re-monitored every 6 months at or above the action level and every 3 months above the PEL.

29 CFR 1910.95

Occupational Noise Exposure

Sets an 85 dBA action level and a 90 dBA PEL with a 5 dB exchange rate, requires repeat monitoring when changes may raise exposure, and requires audiograms at least annually.

29 CFR 1910.1020

Access to Exposure and Medical Records

Exposure records, including workplace sampling and biological monitoring results that measure absorption, are kept at least 30 years, and medical records for the length of employment plus 30 years.

How the Odiz App Helps

Industrial Hygiene keeps every survey, result, finding and re-survey date in one place.

🧪

Eight Survey Types

Airborne chemicals, surface and skin, biological monitoring, physical hazards, biological agents, indoor air quality, control checks and bulk materials, each with its own agents, units and limits.

📏

Results Checked Against Limits

Each result is compared with its OSHA, NIOSH or custom limit and shown as a percent of the limit, with unit conversion, mixture index and noise dose.

🛠️

Hazardous Results to Corrective Actions

Results at or above the action level, at 50% or more of the limit, or over it need a finding and go to Corrective Actions on sign-off.

📅

Re-Survey Reminders

Re-survey dates go to the calendar, with reminder emails 1 year, 6 months, 3 months, 1 month, 1 week and 1 day before they are due.

📨

Results Letters

Print a letter for each person sampled with only their own results, record the day it was given and track the 15-working-day notice.

📄

Reports and Lab Imports

Export PDF survey reports and Excel workbooks, and import samples from a lab report PDF or photo with AI, then check every value.

Keep exposure surveys, results and re-survey dates together, so hazardous results get fixed and monitoring stays on schedule.

Exposure Monitoring FAQs

Common questions about industrial hygiene surveys, OSHA limits and how the Odiz App handles results.

+−Which limits does the app compare results with?

Airborne results are compared with OSHA PELs from 29 CFR 1910.1000 Tables Z-1, Z-2 and Z-3 or the substance-specific standards, including 8-hour TWA, STEL and ceiling limits. You can also compare a result with a NIOSH or custom limit, and the app converts between ppm and mg/m3 when the molecular weight is known.

+−What counts as a hazardous result?

A result over its limit or failed, at or above the action level, or at 50% or more of the PEL, STEL or ceiling. Each hazardous result needs a finding before the survey is finalized, and it goes to Corrective Actions when the survey is signed off.

+−How often must exposures be re-monitored?

It depends on the substance and the result. Silica and lead are re-monitored at least every 6 months at or above the action level and every 3 months above the PEL (1910.1053(d)(3), 1910.1025(d)(6)), while Table Z agents have no fixed interval. The app shows the longest interval OSHA allows for the results and warns if the schedule is longer.

+−Does the app help notify employees of their results?

Yes. It prints a results letter for each person sampled with only their own results, records the day letters were given, and tracks the 15-working-day due date where a substance-specific standard requires notice. Overdue notices are flagged on the Industrial Hygiene home page.

+−Who can see exposure results?

Industrial Hygiene records are restricted to people with the IH Sampler or IH Reviewer role and organization owners, because they hold the names and results of the people sampled. Only an IH Reviewer or an organization owner can sign off a survey.

+−Can lab reports be imported?

Yes. Upload the lab or consultant report as a PDF or a photo, and AI reads the sample IDs, people, pumps, times and results into samples you review before adding them. The report is kept with the survey.

Exposure monitoring only protects workers when results are compared with the right limit, acted on and repeated on time. Industrial Hygiene in the Odiz App records air, surface, biological, noise and control surveys, checks every result against its OSHA limit and keeps the re-survey schedule, employee notices and reports with the survey.

Key features

  • Eight survey types: airborne chemicals, surface and skin, biological monitoring, physical hazards, biological agents, indoor air quality, control checks and bulk materials, each with its own agents, units and limits.
  • Results checked against limits: each sample is compared with its OSHA limit, or a NIOSH or custom limit, and shown as a percent of the limit, with mixture and noise dose calculations.
  • Hazardous results to Corrective Actions: results at or above the action level, at 50% or more of the limit, or over it need a finding and become corrective actions when the survey is signed off.
  • Re-survey scheduling: the app suggests an interval, warns when a schedule is longer than OSHA allows for the results, and sends reminders 1 year, 6 months, 3 months, 1 month, 1 week and 1 day before a re-survey is due.
  • Employee notification: printable results letters give each person only their own results, and the app tracks the 15-working-day notice where a substance-specific standard requires it.
  • Reports and lab imports: PDF survey reports, Excel workbooks, and AI-assisted import of samples from a lab report PDF or photo, with the lab report kept with the survey.

How it works

An IH Sampler chooses the survey type, records the location, reason and controls in place, and adds each sample with the person or area, sampling times and result, or imports the samples from the lab report. Results are compared with their limits as they are entered, and every hazardous result needs a finding before the survey can be finalized.

An IH Reviewer or organization owner reviews the finalized survey and signs it off with a drawn signature. Sign-off sends hazardous results to Corrective Actions and puts the re-survey date on the calendar. Results letters, employee notification dates and the survey report stay with the record, and access is limited to people with an IH role and organization owners because the results identify the people sampled.

Standards

Airborne results are compared with OSHA's Table Z limits in 29 CFR 1910.1000 and the substance-specific standards in 29 CFR 1910.1001-1053, which add action levels, periodic monitoring schedules and employee notification. Noise follows 29 CFR 1910.95 (action level 85 dBA, PEL 90 dBA), and exposure and medical records fall under 29 CFR 1910.1020. Where OSHA has no specific standard, such as heat, mold and indoor air quality, the app shows the guidance it applies, including ASHRAE 62.1, 55 and 188. Related tools: Corrective Action Management, Chemical Management & HazCom (SDS) and Analytics.

Write a review

Related products

Incident & Near Miss Reporting
EHS Management Apps

Incident & Near Miss Reporting

Incident and near miss reporting app for injuries, near misses, hazards and property damage. Workers report fr…

Request quote

SKU ODIZ-15477

View →
Chemical Management & HazCom (SDS)
EHS Management Apps

Chemical Management & HazCom (SDS)

Chemical management and SDS app for OSHA hazard communication. Find any chemical and its safety data sheet, ap…

Request quote

SKU ODIZ-15473

View →
Corrective Action Management
EHS Management Apps

Corrective Action Management

Corrective action management app for failures found in inspections, assessments, validations, stop time measur…

Request quote

SKU ODIZ-15474

View →