Safety Through Innovation · Made in the USA

Dock leveler inspection app for dock levelers, dock plates, dock boards and bridge plates. The Odiz App checklist draws on OSHA 29 CFR 1910.26 and 1910.22: load capacity and rating, structural damage, slip and trip hazards, run-off protection, securing of portable dockboards, handholds and leveler operation. Record the rated capacity once, then inspect monthly.
Request information
OSHA's walking-working surfaces rules cover dockboards, which include dock levelers, dock plates and bridge plates. The Odiz App checklist references these rules and defaults to a monthly inspection.
Dockboard Requirements
Walking-Working Surface Conditions
Dockboard Definition
Default Inspection Frequency
Problems that show up on dock levelers and dock plates, and the checklist items that catch them.
Unknown or Exceeded Capacity
Missing or unreadable rated capacity markings, or dockboards used for loads beyond what they can support.
Structural Damage
Cracks, broken welds, bent lips or damaged hinges that affect safe use.
Slippery Surfaces
Oil, grease or debris on the deck, or tread worn down so feet and wheels lose traction.
No Run-Off Protection
Dockboards placed into service on or after January 17, 2017 without a means to keep transfer vehicles from running off the edge.
Unsecured Portable Plates
Portable dock plates not anchored or locked in place, or without enough contact to keep them from shifting.
Damaged Units Left in Service
Defective dockboards still in use instead of being removed from service or repaired.
A dock leveler or dock plate is the bridge between the building and the trailer. When a plate shifts, cracks or gives way under a loaded forklift, the truck can drop into the gap and the operator can be seriously hurt.
OSHA 29 CFR 1910.26 requires dockboards to support the maximum intended load and portable dockboards to be secured, and it requires run-off protection on dockboards placed into initial service on or after January 17, 2017 unless there is no run-off hazard. A monthly check with a dated record shows the condition of each unit and when defects were found and fixed.
Key criteria cited in the Dock Levelers and Dock Plates checklist.
Load Capacity
Dockboards are capable of supporting the maximum intended load, in line with the general load requirement for walking-working surfaces in 1910.22(b).
Run-Off Protection
Dockboards put into initial service on or after January 17, 2017 are designed, constructed and maintained to prevent transfer vehicles from running off the edge, unless the employer demonstrates there is no run-off hazard.
Securing Portable Dockboards
Portable dockboards are anchored in place or held by equipment or devices that keep them from moving out of a safe position. Where that is not feasible, there is enough contact between the dockboard and the surface to prevent movement.
Surface Hazards
Walking-working surfaces are kept free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow and ice.
A consistent way to inspect every dock leveler and dock plate on site and follow up on what fails.
Lookup by Tag or ID
Scan the QR tag at each dock door or on a portable plate, or enter its Equipment ID, to open its record and checklist.
Rated Capacity on Record
The rated capacity is stored with each dockboard for reference during inspections.
Photos of Defects
Failed items require a photo, a description and a recommendation.
Tracked Fixes
Each failure becomes a corrective action with an assignee, a due date and a verification step.
Overdue Alerts
Upcoming and overdue inspections show on the To-Do list and in the Daily Overdue Inspection Digest.
Pass Rates in Analytics
Analytics shows submissions, pass rate and failures by equipment type, including dock levelers and dock plates.
Keep a dated history of every dock leveler and dock plate inspection, with the inspector's name and a PDF report on each record.
Common questions about dock leveler and dock plate inspections in the Odiz App.
29 CFR 1910.21(b) defines a dockboard as a portable or fixed device that spans a gap or compensates for a difference in elevation between a loading platform and a transport vehicle, including bridge plates, dock plates and dock levelers. The Odiz App uses one checklist for all of them, with N/A for items that do not apply.
Under 1910.26(b), dockboards put into initial service on or after January 17, 2017 must be designed, constructed and maintained to prevent transfer vehicles from running off the edge, unless the employer demonstrates there is no run-off hazard.
It checks for anchoring, locking, curbs, pins, legs, a lip or other means to keep the plate in a safe position under 1910.26(c), or enough surface contact where anchoring is not feasible. It also checks for handholds or other means of safe handling under 1910.26(e).
Dock levelers and dock plates default to a monthly inspection, and the next due date follows that frequency after each submission. Overdue units appear in the To-Do list and the Daily Overdue Inspection Digest.
A failed item requires a photo, a description and a recommendation, and the finding moves into Corrective Actions with an owner, a due date and a verification step. The checklist also asks whether defective dockboards have been removed from service or corrected.
Yes. The Odiz App includes a training module on dock levelers, and completions count toward each worker's training record.
Dock levelers and dock plates carry forklifts and loads many times a shift, and wear, impact damage and debris build up between maintenance visits. The Dock Levelers & Dock Plates inspection in the Odiz App covers 15 checks on load capacity, structural condition, footing, run-off protection, securing and operation, and records who inspected each dockboard and when.
Add each dock leveler or portable dock plate in the app and attach a QR tag. The add-equipment wizard asks for the manufacturer and model, and if that model is already in the shared catalog its details fill in automatically. At inspection time, open Equipment Lookup, scan the tag or enter the Equipment ID, and answer each item Pass, Fail or N/A. Inspections can be assigned to one or more people, and any assignee can complete them.
Each result is dated, recorded with the inspector's name and saved to the dockboard's inspection history with a PDF report. The next due date follows the monthly default frequency, and overdue units appear in the To-Do list and the Daily Overdue Inspection Digest. For the trucks that cross the dock, see Forklift and Powered Industrial Truck inspections; for storage near the dock, see Pallet Rack and Storage Shelving inspections.
The checklist references OSHA 29 CFR 1910.26 (Dockboards), including 1910.26(a) for load capacity, 1910.26(b) for run-off protection, 1910.26(c) for securing portable dockboards and 1910.26(e) for handholds, along with 1910.22(a)(3) and 1910.22(b) for surface condition and loads, and the dockboard definition in 1910.21(b). These sections are part of OSHA's walking-working surfaces rules. The Odiz App helps you document each check; it does not replace manufacturer-recommended maintenance for powered dock levelers.

Spill kit inspection app for universal, oil-only, HazMat and mercury spill kits. The Odiz App records the kit …
Request quote
SKU ODIZ-15496

Chemical storage inspection app for cabinets, shelves, rooms and cages. The Odiz App checklist draws on OSHA 2…
Request quote
SKU ODIZ-15484

Emergency lighting inspection app for emergency lights, exit signs and combination units. Scan each unit’s QR …
Request quote
SKU ODIZ-7996

Aerial lift inspection app for daily pre-use checks of boom lifts, bucket trucks and other man lifts. The Odiz…
Request quote
SKU ODIZ-15481