Safety Through Innovation · Made in the USA

Environmental compliance audit app for site-level reviews of air, water, waste, chemical reporting, emergency response and compliance management. The Odiz App builds the checklist from federal EPA and OSHA requirements and the facility’s state rules, shows only what applies to the site, and sends findings to Corrective Actions after review.
Request information
Core federal programs in the audit checklist. Requirements for the facility's state are added on top.
Title V Operating Permits
Oil Spill Prevention (SPCC)
Hazardous Waste Generators
EPCRA Tier II Reporting
Typical environmental compliance gaps the audit is designed to bring to light.
Unreviewed Emission Sources
Booths, ovens, boilers or engines are installed without an air permit review or a documented exemption.
Outdated SPCC Plan
The oil spill prevention plan is not reviewed at least every five years or no longer matches the containers on site.
Hazardous Waste Container Issues
Containers are unlabeled, left open or kept past the accumulation time limit for the generator category.
Missed Chemical Reports
Chemical quantities cross Tier II or TRI thresholds without a check, so annual reports are late or missing.
Stormwater Permit Lapses
Inspections, monitoring, annual reports or the stormwater plan required by the permit are not kept up.
No Compliance Calendar
Permit renewals, reports, fees and training deadlines are tracked from memory instead of a register and calendar.
Environmental obligations change with what a site makes, stores and discharges, and many come with fixed reporting deadlines. A missed permit condition, an outdated plan or a late report can lead to agency enforcement and costly corrective work.
A regular site audit against federal and state requirements shows what is in place, what is missing and who needs to fix it. Sending findings to Corrective Actions keeps each gap assigned and tracked until it is verified closed.
Examples of what the audit checks. Each requirement in the app shows the regulation it comes from.
Air Permits and Title V
Every emission source covered by a permit, registration or documented exemption, permit limits and records tracked, and for Title V sources, semiannual monitoring reports, the annual compliance certification and a timely renewal application.
SPCC Plans
Whether oil storage crosses the SPCC thresholds, a Plan that is certified, kept up to date and reviewed at least every five years, secondary containment, inspections and training for oil-handling personnel.
Hazardous Waste Generators
Waste determinations and generator category, container labeling, closure and accumulation limits, EPA ID, manifests, emergency preparedness and training for small and large quantity generators.
Emergency Response
An emergency action plan under 29 CFR 1910.38 and, where employees respond to hazardous substance releases, an emergency response plan and trained responders under 1910.120(q).
The Environmental Site Audit turns a broad regulatory review into a guided, documented checklist.
Federal and State in One Audit
Federal criteria plus state items for all 50 states, DC and Puerto Rico, chosen from the facility's address.
Only What Applies
Facility profile answers hide requirements that do not apply, and Not sure keeps them in.
Pass, Fail or N/A
Each requirement shows its citation, with a description, optional photo and recommended action on a Fail.
Scores by Area
Compliance by area and findings by severity are calculated when the audit is submitted.
Drafts on Any Device
Save a draft and resume the audit later from a phone, tablet or computer.
Findings to Corrective Actions
After review, findings become tasks with assignees, due dates and verification.
The Environmental Site Audit is a point-in-time review against the listed requirements and is not legal advice.
Common questions about running an environmental compliance audit in the Odiz App.
Six areas: air; water; waste; chemical reporting and release notification; emergency response and training; and compliance management. You can audit all six or only the areas you select.
The state in the facility's address decides. The app has state-specific items for all 50 states, the District of Columbia and Puerto Rico, and shows the state agency, stormwater permit and hazardous waste program for the site. Fees and dates change, so confirm them with the agency.
Answers about permits, operations, equipment, storage, waste and chemical quantities decide which requirements appear. Answering Not sure keeps the related requirements in the audit.
Each Fail needs a description and can include a photo and a recommended action. Audits with findings wait in Review Recommendations until a reviewer sends the findings to Corrective Actions, where each one becomes a tracked task.
No. It covers U.S. federal and state requirements. A facility with no U.S. state on file gets federal requirements only, and facilities outside the United States cannot run it.
No. It is a point-in-time review against the listed requirements. Use it to document conditions and assign corrective actions, and confirm regulatory questions with your environmental professional or the agency.
Environmental requirements come from many programs: air permits, stormwater and wastewater permits, oil spill prevention, hazardous waste, chemical reporting and emergency planning, each with its own records and deadlines, plus state rules on top. The Environmental Site Audit in the Odiz App gives auditors one structured checklist for a facility, covering federal requirements and the requirements of the state the site is in.
Select the facility and the areas to audit. Enter the audit details, answer the facility profile, then work through each area page. Drafts can be saved and resumed from any device. The conclusions page records overall observations, good practices and the auditor's signature, and a PDF report is generated when the audit is submitted.
Audits with findings are held in Review Recommendations so a reviewer can check them before they go to Corrective Actions, where each finding becomes a task with an assignee, a due date and verification before it closes. An audit can be marked restricted so only the auditor, organization owners and Odiz staff can see it while it waits for review. Coating usage records kept in the Paint Tracker can support the coating records the audit asks about.
The federal checklist covers air permit applicability and Title V permits (40 CFR Part 70), NESHAP and NSPS rules for coating, engines, boilers and degreasing, stormwater and wastewater permits, SPCC (40 CFR Part 112), underground storage tanks (40 CFR Part 280), RCRA hazardous waste generator status and accumulation (40 CFR Part 262), shipping, manifests and DOT hazmat training, universal waste (40 CFR Part 273), used oil, EPCRA Tier II (40 CFR Part 370) and TRI (40 CFR Part 372) reporting, emergency action and HAZWOPER emergency response (29 CFR 1910.38 and 1910.120), the Risk Management Program (40 CFR Part 68) and compliance management. The audit is a point-in-time review against the listed requirements and is not legal advice. Fees and dates change, so confirm state requirements with the agency.